Thursday, February 28, 2019

How Safety Environment An Industry Can Produce While Avoiding Installation Insulating Mat?

Nowadays not only the demand for rubber sheets are in growing but also it is a really tough job for the online rubber matting suppliers to perform the same way as they promise online for every product.

That’s why when someone finding an online insulating mat, professional assistance can help you instantly. So, if you somehow fail to get the products within the deadline, take genuine online assistance.

Insulating mats should be the most priority of a company where workers work with electrical appliances. Quality based insulated rubber mats are highly economical and suitable for general usage purpose also.

Insulation mats are highly electrical resistant and they also protect from mortal shocks generated by high voltage equipment. These sheets are manufactured as per the latest Indian Standard. These insulation mats are manufactured using elastomer. It is available in 2mm, 2.5mm & 3.0mm depending upon working voltage.

The Application Area Of Insulation Mats

·        Near HT/LT Control Panels
·        In front of Switchboards
·        Electrical Substations
·        Around Buss Bars
·        Transformers, Generator & Lift Room
·        Outdoor/Indoor On-site use on Live Equipment

Are Insulating Mats Really Helpful For The Safety Of The Workers?

Generally, insulating mats are used to cover the floor below the control panels. Besides, these insulation mats are also used for the safety of workers while installing electrical equipment because of the possibility of leakage of current.
·        Always verify the absence of voltage & use VR gloves & tools
·        Establishment of worker safety boundaries from electrical shock
·        Wearing arc-rated daily wear and a face shield
·        Try using GFCI with cord connected tools & extension cords
·        Measure, audit, and improve the electrical safety processes

Electrical Insulating Mats


The Purpose Of Electrical Rubber Mat In Electrical Purpose

Electrical rubber mats are basically, the high-quality industrial products whose object is to give insulation in electrically sensitive workplaces of commercial or industrial importance.

Manufacturing Process Of Rubber Mats

Generally, rubber mats are made out of natural rubber having good electrical resistance and mechanical properties. These products are available from different ranges in standard size with a checkered or fluted design.

The Features & Values Of Rubber Mats

Standard Size & Design: 1) 1.0 Mtr. Wide x 2.0 Mtr. Long
                                         2) 3.0 Ft. Wide x 6.0 Ft. Long

Custom Size & Design: Max. width upto 1000mm, length upto 2000mm
                                     and thickness up to 50mm available

Standard Colour: Black (Red & other colors also available on request)

Manufacturing Tolerance: ±10% on thickness
                                              ±5% on length
                                             ±2% on width

The Application Area Of Electrical Rubber Mats

·        In front of Switchboards
·        Electrical Substations
·        Around Buss Bars
·        Near HT/LT Control Panels
·        Transformers, Generator & Lift Room
·        Outdoor/Indoor On-site use on Live Equipment
Basically, used these insulating mats for electrical purposes are highly beneficial as they protect the workplace from electrical calamity.

Advantages Of Taking Insulating Mats From An Online Industry

·        Customer Satisfaction
·        On-Time Delivery
·        Affordable Pricing
·        Good Product Quality
·        Comprehensive Infrastructure
·        Outstanding Technology

Check The Details Of Your Requirements While Ordering

·        Working Voltage
·        Colour
·        Thickness
·        Length & Width

·        Total Quantity Required

Wednesday, February 20, 2019

Your Safety Is In Your Hand. Get The Prime Ideas About Preventing The Electrical Hazards

An insulator is a material which limits the transfer of heat and electricity. Insulated rubber mats are very useful and popularly recommended for the safety of the workmen against electrical hazards.

Insulating mats are mainly used for covering the industrial floor below the control panels. Basically, insulating mats are used for the safety of workers while installing and operating electrical equipment. The reason is as there is a possibility of leakage of current.

How To Prevent Electrical Accidents In Your Workplace?

  •         Use the equipment which is grounded or double insulated

  •         Don’t plug & overload multi-outlet bars

  •         Try minimizing the use of extension cords

  •         Never plug two extension cords together

  •         Try not to run electrical cords through pedestrian aisles

  •         Always unplug or disconnect machines before servicing or repairing

  •         Don’t ignore any warning signs like – unusual noise, smokes or sparks etc.

  •       Inspect the cords and equipment daily basis to avoid any unusual incidents

  •         Never ever touch any electrical pieces of equipment when your hands are wet

  • There are six types of specialized electrical insulating mats are available as per the Indian Standard & International Standard.


As Per Indian Standard

      Insulating Mats (IS 15652:2006)
      ISI Marked Insulating Mats (IS 15652:2006)
      Electrical Rubber Mats (IS 5424:1969)

As Per International Standard

      Insulation Mats (IEC 61111:2009)
      Insulation Matting (ASTM-D-178)
      Insulating Matting (AS/NZS – 2978:1995)

The insulation matting is manufactured as per the AS/NZS 2978:1995 standard set by the Joint Standards Australia/New Zealand Committee El/4. These electrical safety matting insulate and protect from mortal shocks generated by electrical equipment. If you want to buy all types of electrical insulating matting including switchboard matting to protect from electrical shock, choose the right one.

insulating mats


The Application Area Are As Follows:

  •         Near HT/LT Control Panels

  •         Electrical Substations

  •         In front of Switchboards

  •         Around Buss Bars

  •         Transformers, Generator & Lift Rooms

  •         Indoor/Outdoor On-site use on Live Equipment


Rubber mats are highly recommended for the safety of the workmen against electrical hazards. These electrically insulated rubber mats are highly economical and suitable for general use also. The material used in our insulating rubber mat is made out of natural rubber having good electrical resistance and mechanical properties.

Take A Glance About The Characteristics & Values Of Rubber Sheet

Material Composition – Special rubber compound of high-quality natural rubber free from any insertion

Tensile Strength – 50 kg/cm2 (min.)

Elongation at Break (E.B.) – 250% (min.)

Leakage Current – 10mA (max.)

Water Absorption – 4% (max.)

Compression Set – 10% (max.)

Working Temperature – 0°C to 55°C

Insulating rubber mats should be the most priority of a company where workers work with electrical appliances. These insulated rubber mats are highly economical and suitable for general usage purpose also.

Whenever you need rubber mats for electrical purpose online just pick the right stuff from the Google, so that as you can get your rubber mats in time with the latest version of the document within the scheduled deadline.

What Are The Benefits Of Insulating Mats While Taking From A Professional Industry?

  •         Customer Satisfaction
  •         On-Time Delivery
  •         Affordable Pricing
  •         Good Product Quality
  •         Comprehensive Infrastructure
  •         Outstanding Technology

Wednesday, January 30, 2019

How You Define The Role Of The Insulating Mats In The Industrial Sectors?

Nowadays the demand for rubber sheets are in growing demand and it is a really tough job for the online rubber matting suppliers to perform the same way as they promise online for every product.

High-voltage insulating mats are highly economical and suitable for general use also. The material used in our insulating rubber mat is made out of natural rubber having good electrical resistance and mechanical properties.

Features Of High-Voltage Insulating Mats

  •         In compliance with IS 15652:2006
  •        Fire resistant
  •         Resistant to acids, transformer oil, and alkalis
  •         Easy to paste and install
  •         High tensile strength
  •         Water & moisture proof
  •         Compatible with Ac and DC electrical installations
  •        Excellent expansion properties
  •        No use of metallic products


These are manufactured as per the latest Indian Standard. These insulating mats are used for the safety of workers while installing and operating electrical equipment because of the possibility of leakage of current.

According to the National Fire Protection Association – Roughly half (50.9%) of home electrical failure fires involved electrical distribution or lighting equipment in 2015-2019



Application Area Of High-Voltage Insulating Mats

  •         Near HT/LT Control Panels
  •         Electrical Substations
  •       In front of Switchboards
  •       Around Buss Bars
  •       Transformers, Generator & Lift Rooms
  •       Outdoor/Indoor On-site use on Live equipment


Electrically insulated rubber mats are highly economical and suitable for general use also. The material used in our insulating rubber mat is made out of natural rubber having good electrical resistance and mechanical properties.

Whenever you need insulating rubber mats online just pick the right stuff from Google, so that as you can get your rubber mats in time with the latest version of the document within the scheduled deadline.

Six types of specialized electrical insulating mats are available as per Indian Standard & International Standard.

As Per Indian Standard

  •        Insulating Mats (IS 15652:2006)
  •        ISI Marked Insulating Mats (IS 15652:2006)
  •        Electrical Rubber Mats (IS 5424:1969)


As Per International Standard

  •        Insulation Mats (IEC 61111:2009)
  •        Insulation Matting (ASTM-D-178)
  •        Insulating Matting (AS/NZS – 2978:1995)


Insulated rubber mats have been on the market for a long time but there are still some questions about them that everyone is asking. Well, in that case only rubber mat expert guide you step-by-step as below:

How Long Can I Use My Rubber Mat?

It depends on what kind of rubber mat you have. However, there are several rubber mats on the market that can last for many years.

Is It Necessary To Have An Electrical Rubber Mat For My Business?

If your business mostly deals with big electrical equipment, you should use these mats. They help prevent accidents and increase safety within the workplace.

Is It Okay To Use Any Kind Of Rubber Mat For Electrical Safety?

No. Not all rubber mats are suitable for electrical use. Choose mats that have passed the necessary electrical standards. This is for your own safety.

Rubber mats are readily available on the market but you should know the basic facts so that you purchase the best alternative to suit your specific requirements.


One of the essential need of the safety tool in today’s corporate sectors is Insulation Mats. The material used in our insulating rubber mats is made out of natural rubber having good electrical resistance and mechanical properties. 

Monday, December 31, 2018

How Safe Are You Without Installing Electrical Insulating Mats?

Safety Starts With Awareness, Awareness Starts With You

Electrical insulating mats are used for protection and covering the floor below the control panels. These electrical insulating mats are mainly used for the safety of workers while installing and operating electrical equipment because of the possibility of leakage of current.

The Manufacturing Process Of Electrical Insulating Mats
Insulating mats are manufactured using – elastomer that containing, latex, rubber, and elastomeric compounds that might be natural, synthetic or mixture of both all along with anti-skid aberrations on the top to avoid slippage and a smooth lower surface. It is available in 2mm, 2.5mm & 3.0mm thickness depending upon the working voltage.

Did You Know?

Roughly half (48.9%) of home electrical failure fires involved electrical distribution or lighting equipment in 2011-2018

The Application Area Of Electrical Insulating Mats

·        Near HT/LT Control Panels

·        Electrical Substations

·        In front of Switchboards

·        Around Buss Bars

·        Transformers, Generator & Lift Rooms

·        Outdoor/Indoor On-site use on Live equipment


Simple Tips For Electrical Safety (National Fire Protection Association)

Avoid Overloading Outlets

Plug the only high-wattage appliance into each receptacle.

Follow Wattage Recommendations

Only use bulbs that match a lamp’s wattage.

Turn Off The Power

Always turn off appliances and devices when you leave the room. Many electrical fires are started by overheating outlets or wires.

Keep Away From Water

Electrocution is a risk when an electrical device gets wet. It keeps all the electrical devices away from water.

Call An Electrician

For any electrical work you do around the house, if any electrical outlet feels hot, you hear crackling noises, or you notice frayed or split wiring.

Insulated rubber mats are highly recommended for the safety of the workmen against electrical hazards. Electrical rubber mats are highly economical and suitable for general use as the material is used as insulating rubber mats which are made out of natural rubber having good electrical resistance and mechanical properties.

Comprehensive Features of Electrical Insulating Mats

·        In compliance with IS 15652:2006
·        Fire resistant
·        Withstand heavily loaded of breaker trolley
·        Resistant to acids, transformer oil, and alkalis
·        Easy to paste and install
·        High tensile strength
·        Water & moisture proof
·        Compatible with Ac and DC electrical installations
·        Excellent expansion properties
·        No use of metallic products



The Summary Of Characteristics & Values Of Electrical Insulating Mats

Material Composition: Combination of rubber & synthetic polymers

Tensile Strength (T.S.): 15N/mm2 (min.)

Elongation at Break (E.B.): 250% (min.)

Leakage Current: 10mA (max.)

Flame Retardance: Extinguishes within 5 secs (max.)

Insulating Resistance with Water when tested at 500V: 1,00,000 MW (min.)

Acid, Alkali & Oil Resistance: T.S. & E.B. not less than 80% of the original value

Working  Temperature: -10°C to 55°C

Do You Think Insulating Mats Can Be Categorized?

Though there are different types of electrical insulating mats are available in the market but typically there are six types of standard & specialized electrical insulating mats are available with both Indian Standard & International Standard.

As Per Indian Standard:

î  Insulating Mats (IS 15652:2006)
î  ISI Marked Insulating Mats (IS 15652:2006)
î  Electrical Rubber Mats (IS 5424:1969)

As Per International Standard:
î  Insulation Mats (IEC 61111:2009)
î  Insulation Matting (ASTM-D-178)
î  Insulating Matting (AS/NZS – 2978:1995)